Viscotaq® Wrap

Print
PDF
Viscotaq® Wrap - Anti-corrosion coating (2”, 4”, 6”, 8” x 33’ rolls)

viscowrap application dist by indumar

Viscotaq® Wrap is a non shielding coating in a wrap form that can be applied without primers, forming a homologue layer after application.  It does not show sliding, dripping or thickness changes since it is a solid with a true melting point (around 150 C).  Applications

  • Soil to air transitions
  • Encapsulations of asbestos pipe, lead base paints etc,
  • Tank Chimes
  • Flange and Valve protection
  • River Crossings
  • Water Proofing
  • Prefab Joints
  • Roof seams, penetrations, cracks
  • Manholes
  • Industrial Applications

 

Technical Information

Property Value Method
Glass transition temperature -35 ºC/-31ºF DSC, ASTM E1356-08
Material state Solid NA
Melting point >+150 ºC/302 ºF DSC, ASTM E1356-08
Yield point Yes NA
Dripping behavior (+100 ºC) No visual dripping (1000 hrs) NA
Water vapor permeability <0.0050 g/m2/24mmHg ASTM D1653-03
Water absorption <0.3% ASTM D570-98
Water penetration <0.14%, 1800 hrs,6V, 3% NaCl ASTM G9-87
Dissipation Factor 0.135, 1500 hrs, 20 KHZ ASTM G9-98
Pore Resistance > 109, 1500 hrs, RI/RO 1-1.4 ASTM G1, G3, G5, G10, G19
Hardness 36 Shore A ASTM D2240-04
Impact Strength >15 J (self healing) EN 12068
Impact Strength 13.6 J (system intact) CSA Z245.20-12.12
Peel resistance 20ºC/68 ºF 3 mm/min CSA Z245.21-06, 300 g
Peel resistance 5 ºC/68 ºF 0 mm/min CSA Z245.21-06, 300 g
UV/Weathering cycle test Excellent 1000 hrs, ASTM D4587-05
-30ºC to +70ºC
-22ºF to +158ºF
Wet adhesion test Class 1 rating, cohesive fracture CSA Z245-20-06 Sec 12.14
Cathodic Disbondment < 3 mm, 30 days ASTM G8, 23 ºC/74 ºF
Temperature range -35 ºC to +100 ºC/-43 ºF to +212 ºF NA
Flexibility No cracking CAN Z45.20,12.11
Thickness 70 mil-100 mil(total system)/2-3 mm NACE SP 0188
Shear test 0.0009 mm/min top 0 mm bottom Modified Alyeska Shear,
18.6 24 hours,
50 hrs: 0 mm kg load, 6.8 kg force
Technical Information
Property Value Method
Glass transition temperature -35 ºC/-31ºF DSC, ASTM E1356-08
Material state Solid NA
Melting point >+150 ºC/302 ºF DSC, ASTM E1356-08
Yield point Yes NA
Dripping behavior (+100 ºC) No visual dripping (1000 hrs) NA
Water vapor permeability <0.0050 g/m2/24mmHg ASTM D1653-03
Water absorption <0.3% ASTM D570-98
Water penetration <0.14%, 1800 hrs,6V, 3% NaCl ASTM G9-87
Dissipation Factor 0.135, 1500 hrs, 20 KHZ ASTM G9-98
Pore Resistance > 109, 1500 hrs, RI/RO 1-1.4 ASTM G1, G3, G5, G10, G19
Hardness 36 Shore A ASTM D2240-04
Impact Strength >15 J (self healing) EN 12068
Impact Strength 13.6 J (system intact) CSA Z245.20-12.12
Peel resistance 20ºC/68 ºF 3 mm/min CSA Z245.21-06, 300 g
Peel resistance 5 ºC/68 ºF 0 mm/min CSA Z245.21-06, 300 g
UV/Weathering cycle test Excellent 1000 hrs, ASTM D4587-05
-30ºC to +70ºC
-22ºF to +158ºF
Wet adhesion test Class 1 rating, cohesive fracture CSA Z245-20-06 Sec 12.14
Cathodic Disbondment < 3 mm, 30 days ASTM G8, 23 ºC/74 ºF
Temperature range -35 ºC to +100 ºC/-43 ºF to +212 ºF NA
Flexibility No cracking CAN Z45.20,12.11
Thickness 70 mil-100 mil(total system)/2-3 mm NACE SP 0188

Shear test 0.0009 mm/min top 0 mm bottom Modified Alyeska Shear, 18.6 24 hours, 50 hrs: 0 mm kg load, 6.8 kg force

 mn k kj 

Directions for Use 

Surface must be clean, dry and free from dust/dirt and loose particles. Minimum sp 2 cleaning. Apply inner wrap with 10% overlap, min 0.5 inch by wrapping with some tension. Use a holiday detector (15 kV) to ensure the system is free from any voids. Apply outer wrap by wetting the product with/in water and apply with 50% overlap minimum. Apply high tension during wrapping. Product should be applied within 45 minutes after opening the pouch. Material is ready for backfill in 4 hours. Temperature range after application: -35 ºC to 135 ºC (-31 ºF to 275 ºF).

About InduMar

InduMar Products, Inc. has been providing leak repair solutions for 25 years. We operate in all markets where pipe leaks are a problem. In particular our areas of expertise lie in:

  • Refinery/Petrochemical
  • Offshore oil and gas production
  • Commercial Marine
  • Mining
  • Power
"Pipe was broken by a backhoe and we repaired it to keep moisture from getting in the wires. It worked very well."