Toll Free: +1 (800) 523-7867
|

Stop It® Pipe Repair System

Stop It® CR-E

Mechanical Reinforcement Products

Stop It® CR-E

Off-the-shelf solutions may not work when you’re dealing with a thin, cracked or fractured pipe wall. Sometimes, you need something tailored for your unique situation.

STOP IT® CR-E  is a state-of-the-art epoxy-based composite repair system, so your maintenance team won’t have to take the time and resources to combine solutions into an ad hoc patch. After talking with your representatives to get the project requirements, InduMar designs an application that meets DOT-governed pipelines and your exact needs.

This engineered composite kit consists of a hybrid fabric that employs high-grade E-glass and Kevlar® yarns arranged in a multi-axis layout that maximizes the composite strength. Its exceptional toughness resists cracking and can handle temperatures up to 450°F.

  • The pre-treated fabric assures the micro-fibers are significantly stronger than an untreated lay-up.
  • The two-part epoxy resin grade is selected for your application type. Custom formulations give our product exceptional properties of flexibility, adhesion, toughness, chemical resistance, thermal resistance, vibration and more. Special grades are available to handle your special situations.
  • STOP IT® CR-E kits ship to the field with all components pre-measured and factory sealed. Everything is included: composite fabric, two-part epoxy resin, primer, stirring sticks and UV paint. The technician simply lays out a pre-measured reinforcement fiber section, mixes and applies the pre-measured epoxy resin components to the reinforcement. No measuring is required in the field and performance tolerances are tightened with controlled fabric/epoxy resin ratios.
CR-E Epoxy Systems | Engineered Pipe Repair
STOP IT® CR-E epoxy-based composite repair system

Maximum Temperature: 450°F (High temp. epoxy resin system)

Cure Time: 8 hours nominal at 77°F to full cure (Standard epoxy resin system)

Working Time: 30 minutes at 77°F (Standard epoxy resin system)

Part No Description Case Quantity Case WT
(lbs)
** Contact InduMar
Composite Properties
With STD Resin
CR-E1 CR-E3 CR-E22 CR-Ec2
Per Ply Thickness .034″ nominal .017″ nominal .048″ nominal .045″ nominal
Tensile Strength
Warp Direction
55,900 psi 48,874 psi 44,199 psi 70,893 psi
Tensile Modulus
Warp Direction
2.49×106 psi 2.64×106 psi 2.38×106 psi 5.48 Msi
Load Per Ply 1,900 lbs 823 lbs 2,113 lbs 3,148 lbs