Toll Free: +1 (800) 523-7867
|

Oil and Gas Decommissioning

Case Study

Offshore Decommissioning Natural Gas Line Repair

Challenge:

4-inch carbon steel natural gas lines had major wall loss and pinhole leaks due to corrosion. These leaks prevented the pipes from being pressurized in order to pig, flush and plug the lines for removal.

corroded carbon steel natural gas lines
  • Product
    Stop It® Pipe Repair System
  • Industry
    Refinery/Petrochemical
  • Location
    Ocean
  • Application Time
    2 Hours

Solution:

These 4” natural gas lines were repaired using multiple rolls of InduMar’s extra-large 4” x 25’ Stop It® Pipe Repair System

Stop It® is an easy to install, fast setting fiberglass composite system designed for pipe leak and rehabilitation repairs during the decommissioning process.

  • Pressure to 400 PSI
  • Temperatures to 500° F
  • 30 Minute cure time
  • Minimal surface prep
  • No hot work or special tools
  • Chemical resistant

Stop It® is compliant with US DOT 49CFR parts 192 and 195. Testing was performed under the ASMEPCC-2 Article for ASME B31.1, B31.4 and B31.8

Offshore Decommissioning Natural Gas Line Repair

“InduMar Products provided us a quick solution with a great product that was cost effective and easy to install, which allowed us to complete this project on time and on schedule.”

Complete the form below to request documents.

* Indicates Required Selection

"*" indicates required fields

Please select each product for which information is being requested. Multiple products may be selected at the same time. Documents will be immediately forwarded by email.
For which products are you requesting documents? (select all that apply)*

close-link
error: Content is protected !!